Single Loop, Single Room Pump Control Packs

Single Loop, Single Room Pump Control Packs making it the easy way to control one room

Showing all 5 results

  • Reliance Underfloor Heating Overheat Stat

    Reliance Pre-Wired Connection Box with Limit Thermostat for Underfloor Heating Single Room Control Pack

    Quick View £47.79 
    Reliance Pre-Wired Connection Box with Limit Thermostat for RWC Single Room UFH Control Pack no UFHC980352
  • Underfloor Single Circuit Pump Control, Programmable Thermostat & Valve

    Underfloor Heating Single Circuit Pump Control, Programmable Thermostat and Valve

    Quick View from £369.91 

    Underfloor Heating Room Temperature Single Circuit Pump Control Pack

    Made in EuropeThe Komfort Underfloor Heating Temperature Control Pack is all you the electrical components that you will require to operate the single underfloor heating circuit to fire the boiler and main heating pump. The Komfort Underfloor Heating Temperature Control Pack will satisfy 3 kw of heating surface area. The Pack comprises of - 1 x A Rated Wilo Single Circuit Underfloor Heating Pump Unit 1 x 2 way Straight Valve with 15 mm Copper pipe connections 1 x 4 wire Actuator 1 x Thermostat of your choice. Connects for your underfloor heating pipework will need to be purchased separately from https://underfloorparts.co.uk/product-category/pipe-fitting-adaptors/ Pipe and wiring details can be supplied.

    "Manufacturer of the Year"

    Pump Industry Awards - Finalists.

     Wilo are proud to announce that we have been named finalists in the Pump Industry Awards 2016 "Manufacturer of the Year" category.

     
  • Single Loop/Circuit Thermostatic Underfloor Heating Pump Control Pack

    Single Loop/Circuit Thermostatic Underfloor Heating Pump Control Pack

    Quick View £175.95 
    Made in EuropeKomfort Single Loop - Circuit Thermostatic Wilo A Rated Pump Control Pack the perfect answer for Extension & Conservatories. The Komfort Underfloor Heating Pump Control will satisfy floor areas up to 40 m² with a max heating load of 3 kw., the unit comes complete with Thermostatic Blending valve to lower the water temperature required within the underfloor heating system. The Pump Control unit has a built in flow switch to allow the water to continue circulating until the water temperature has cooled sufficiently for the pump to turn itself off, the unit is prewired ready to fit a simple plug top or to wire in with a thermostat system.This system when wired and plumbed correctly it can operate independently to the radiator system. The outlet connection to the underfloor heating system is supplied has 1/2" Female BSP. For fittings to suit you underfloor heating pipe size can be obtain by going to   https://underfloorparts.co.uk/product-category/pipe-fitting-adaptors

    "Manufacturer of the Year"

    Pump Industry Awards - Finalists.

     Wilo are proud to announce that we have been named finalists in the Pump Industry Awards 2016 "Manufacturer of the Year" category.

  • Single-Room-Pack-with-Black-UPS2-Grundfos-A-Rated-Pump

    Reliance Underfloor Heating Single Circuit / Room UFH Pump Control Pack UFHC 970 352

    Quick View from £212.15 
    The underfloor heating single circuit, zone or single room UFH pump control pack has a Reliance Heatguard thermostatic mixing valve is water temperature control valve for blending or mixing the water to the lower temperature required in underfloor heating systems. Single circuit/zone or single room UFH pump control unit will satisfy floor areas up to 40 m² with a max heating load of 3 kw., supply - 15 mm compression inlet connections. The underfloor heating connections are ½” BSP allowing an adaptor to be screwed into for the correct size of underfloor heating pipes. The  single zone or single room UFH Pump Control pack has  wall fixing back plate. The  single zone or single room UFH Control pack Pump provides a quick and simple installation making is ideal for for any single circuit underfloor heating system including conservatories and room extensions. This underfloor control unit is fitted with the market leading energy efficient A Rated Grundfos UPS2 pump. The UFH single zone or single room pump control unit is usually wired through a room thermostat to offer you an ideal and comfortable underfloor heating system. We are able to offer you a wide range of underfloor heating pipe fittings for use with this underfloor heating single room / zone control unit, please select your required size from the drop down table at the time of making your online purchase. Underfloor Heating Single Zone Pack - Technical data
    • Reliance UFH Heat guard thermostatic mixing valve has an adjustable temperature range of 35 – 65 degrees Celsius.
    • Maximum temperature - 90 degrees Celsius
    • Providing controlled mixed temperature water to underfloor heating systems with a heat output up to 3kW
    • Controls the flow temperature to +/- 2°C even with changing boiler flow and return temperatures
    • Maximum static Pressure - 10 bar.
    • Factory pre-set temperature 35 degrees Celsius.
    • Connections - 15mm compression inlets and ½” F BSP outlets.
    • Grundfos electronic variable speed pump complying to the Energy Using Products Directive.
    • Fail-safe feature
    This is a Genuine Reliance Water Controls Product fitted with a Genuine Grundfos A Rated Pump  
  • Single Loop Thermostatic Blending Valve Assembly

    Underfloor Heating Single Loop Thermostatic Blending Valve Assembly (No Pump)

    Quick View £95.00 
    UNDERFLOOR HEATING SINGLE ROOM CONTROL UNIT Fast and simple to install.Suitable for most floor types. Ideal for room extensions and conservatories up to 40m2. This control unit offers precise control of temperature and flow from all hot water sources. The lightweight and compact design makes it easy to connect directly onto existing pipework without the need for adding extra brackets thus saving time and money. This unit comes without a pump, enabling you to use your own pump. The control unit consists of a mixing valve, isolating valves, flow and return connections fixing bracket.
    •  Flow and return connections to floor pipe circuit are 1/2" Female BSP.
    • Supply Flow and return connections are 15mm compression.
    • For use with 130mm Length Pumps.